Skip to main content

Table 2 Size of QDs as measured by TEM and DLS, and their zeta potential.

From: Folic acid modified gelatine coated quantum dots as potential reagents for in vitro cancer diagnostics

Sample

Core

diameter (nm)

Hydrodynamic diameter (DLS by number) (nm)

Polydispersity index (PDI)

Zeta potential (mV)

Standard deviation of Zeta potential

QD (A)

4.2 (+/- 0.7)

8.2

0.570

-19

1.7

QD (B)

4.8 (+/- 0.8)

27.7

0.312

-52

2.7

QD (C)

4.9 (+/- 0.9)

4.7

0.195

-20

4.1