Magnetic separation and concentration of Aβ 1–42 molecules dispersed at the threshold concentration for Alzheimer’s disease diagnosis in clinically-relevant volumes of sample

Abstract

Background

Alzheimer’s disease (AD) is the leading cause of dementia and loss of autonomy in the elderly, implying a progressive cognitive decline and limitation of social activities. The progressive aging of the population is expected to exacerbate this problem in the next decades. Therefore, there is an urgent need to develop quantitative diagnostic methodologies to assess the onset the disease and its progression especially in the initial phases.

Results

Here we describe a novel technology to extract one of the most important molecular biomarkers of AD (Aβ1−42) from a clinically-relevant volume − 100 µl – therein dispersed in a range of concentrations critical for AD early diagnosis. We demonstrate that it is possible to immunocapture Aβ1−42 on 20 nm wide magnetic nanoparticles functionalized with hyperbranced KVLFF aptamers. Then, it is possible to transport them through microfluidic environments to a detection system where virtually all (~ 90%) the Aβ1−42 molecules are concentrated in a dense plug of ca.50 nl. The technology is based on magnetic actuation by permanent magnets, specifically designed to generate high gradient magnetic fields. These fields, applied through submillimeter-wide channels, can concentrate, and confine magnetic nanoparticles (MNPs) into a droplet with an optimized shape that maximizes the probability of capturing highly diluted molecular biomarkers. These advancements are expected to provide efficient protocols for the concentration and manipulation of molecular biomarkers from clinical samples, enhancing the accuracy and the sensitivity of diagnostic technologies.

Conclusions

This easy to automate technology allows an efficient separation of AD molecular biomarkers from volumes of biological solutions complying with the current clinical protocols and, ultimately, leads to accurate measurements of biomarkers. The technology paves a new way for a quantitative AD diagnosis at the earliest stage and it is also adaptable for the biomarker analysis of other pathologies.

Background

Alzheimer’s disease (AD) is a progressive neurodegenerative disorder with high epidemiological relevance and significant social impact. Although, the molecular causes of AD are not well-defined, it is widely accepted that presence of amyloid plaques in the brain, caused by the aggregation of Aβ1−42 and Aβ1−40 in insoluble oligomers and fibrils, represents one of its main pathological hallmarks. These plaques trigger pathological processes leading to neuronal damage and subsequent cognitive impairment [1,2,3]. An inverse relation exists between the presence of amyloid plaques in the brain - as imaged by in-vivo positron emission tomography - and concentration of Aβ1−42 in cerebral spinal fluid (CSF) even in early patients [4]. It has been also demonstrated that analysis of CSF Aβ1−42 significantly increases the diagnostic accuracy in clinically uncertain cases [5]. Because of that, in 2014, the International Working Group for New Research Criteria for the Diagnosis of Alzheimer’s disease (IWG) proposed a revised version of the diagnostic criteria for AD where CSF levels of Aβ1−42 should be considered as pathophysiological markers at any stage of the disease, preclinical states included [6]. Therefore, sensitive, specific, and robust methods to quantify Aβ1−42 concentrations in body fluids are central in AD research, drug development and clinical management [6, 7]. They are also critically important for early diagnosis as new drugs have recently shown in phase III trials to slow cognitive and functional decline in patients with early AD [8].

Recent technological advances have made it possible to measure Aβ1−42 concentration in CSF using automated assays [9]; yet, novel technical tools are needed to enhance the sensitivity to the level required for fast standardized brain amyloidosis monitoring during the clinical practice [10]. Additionally, measurements of Aβ1−42 concentration are critically sensitive to pre-analytical and analytical biases [6, 11, 12]. Fully automated instruments (from biological fluid handling to detection) could therefore significantly improve the current state-of-the-art.

Microfluidic devices are of great interest for a quantitative measure of AD biomarkers [13] and the use of magnetic nanoparticles (MNPs) can facilitate their miniaturization into lab-on-a-chip platforms as proper functionalization can enable MNPs to selectively bind to the target biomolecule. Subsequently, external magnetic fields can be used for manipulation and detection of the MNP-bound biomolecule [14]. Magnetic actuation can also solve the critical issue in microfluidics: mixing and processing of fluids become inefficient at small scales because of the dominance of capillary and viscous forces [15].

MNPs are used in biomedicine to bind cancer biomarker proteins [16], DNA/RNA sequences [17, 18], bacteria [19], eukaryotic cells [20, 21] or extracellular vesicles [22] for sensing and separation purposes even from complex biological matrices. Their remote control in microchannels have been demonstrated by using rotating magnetic systems [23]. Advanced lithography has also allowed the fabrication of complex patterned surfaces on which the motion of MNPs (and the biomolecules bound to them) can be finely controlled: thin films patterned into arrays of micro-sized soft magnetic structures [24] or electromagnets [25]. Magnetic domain walls in continuous ferromagnetic thin films can also be used to this aim [26].

However, most of those technologies failed to progress into a real-world clinical tool as they require cumbersome external devices and/or elaborate chip designs. As a result, there is an increasing interest in the use of permanent magnets as a simple and effective approach for MNP manipulation [27,28,29].

Here, we report the development of an experimental device for the capture and concentration of Aβ1−42 amyloids in biological fluids, based on magnetic actuation of superparamagnetic MNPs by permanent magnets arranged as in [30]. In comparison with similar devices reported in ref. [27, 28], the magnet arrangement here employed concentrates the MNPs in a clepsydra-shaped configuration (CSC). Its shape is optimized to capture much-diluted molecules and maximizes the MNPs active area for molecular binding as it spans across the entire capillary section while not forming large dense concentrations where most of the MNPs are buried in “dead layers”. We experimentally demonstrate that the device here presented can immune-capture Aβ1−42 molecules uniformly distributed in clinically relevant volumes of fluid – 100 µl – in a range of concentrations clinically relevant for AD early diagnosis [31]. It can also concentrate virtually (90%) all the molecules dispersed in the macroscopic volume of fluid into a nanoliter-sized plug and reliably transport them to a defined point where a sensor can be placed.

Methods

Experimental device

The device is composed of a fork-like magnet holder that keeps two 20 × 5 × 5 mm3 NdFeB magnets with 1.3 T as remanence field (Supermagnete GmbH, Gottmadingen, Germany), symmetrically placed at a fixed edge-to-edge distance of 3 mm. A rotatory motor moves the magnets holder, via a central shaft, along a 0.9 mm wide (internal lumen diameter is 500 μm) medical-grade silicone tube (Silastic®, Dow Corning, Midland, Michigan, USA) wrapped in a two-turn spiral (radius = 40 mm). The longest dimension of the magnets is kept orthogonal to the tube’s direction during the entire rotation. A polycarbonate housing keeps the flexible silicone tube at the midpoint between the magnets and allows the tube endings to be connected on one side to the peristaltic pump feeding the system and on the other to an outlet. The configuration of the magnets and their positioning with respect to the tube is sketched in Fig. 1a. Briefly, the magnets generate a magnetic field with a clepsydra-like shape: it peaks between the magnets along the (local) direction of the capillary but, in the perpendicular direction, has a broad minimum centred at the midpoint. Maxima are located on the magnets (Fig. 1c). Size and position of the tube play a crucial role in the magnetic confinement of the MNPs. Indeed, a 500 μm-wide tube placed at the midpoint between the magnets physically constrains the MNPs in a 250 μm-long slice where the field is fairly constant. There inside the MNPs are confined in a clepsydra-shaped configuration (CSC) spanning across the entire tube’s section (Fig. 1b) resembling the magnetic field distribution. (Fig. 1c). MNPs remain confined in a stable CSC because of the high field gradients along the longitudinal direction (to the tube) attracting MNPs between the magnets. Instead, along the transversal direction, the field gradients are low at the midpoint between the magnets, and this allows the MNPs to disperse across the entire tube’s section. Were the tube wider or displaced from the centre (where the gradients are steeper along the perpendicular direction), the MNPs would be attracted towards higher field regions and ultimately coalesce in dense blobs. A more detailed description of the magnetic configuration has been recently published in [30], where both the static confinement and the possibility to move the clepsydra along microfluidic channels were investigated. Crucially for the application here presented, the CSC remains stable when the magnets are moved along the two-turn spiral tube at a speed of 40 μm/sec, in agreement with previous publication [30].

Fig. 1
figure 1

Reprinted from [30]. c FEM-based simulation of the magnetic field generated by the magnets used in the experimental device by the permanent magnets (PM).

a Configuration of the magnets in the experimental device and its working principle. A couple of magnets are symmetrically placed on the sides of the silicone tube and are moved along following the curvilinear geometry. b Experimental realization of MNP magnetic confinement in a capillary having the same diameter as the internal lumen of the silicone tube used in the experiments. The MNP plug is contained in a 250 μm long section of a 500 μm wide capillary and thus has a volume of 50 nl. Bar is 3 mm long corresponding to the edge-to-edge distance between magnets. The image is oriented as in c. For imaging purposes, the magnetically confined MNP plug is shown in a completely transparent quartz capillary suspended between the magnets.

Synthesis and characterization of MNPs

The synthesis of MNPs functionalized with the Aβ16−20 residue Lys-Leu-Val-Phe-Phe (KLVFF) involves two subsequent steps: preparation of core-shell Fe3O4@SiO2 nanoparticles and surface modification with hyperbranched poly(epsilon-Lysine) dendrons exposing KLVFF sequences at their uppermost branching generation.

Preparation of core-shell nanoparticles

Synthesis of silica-coated magnetite nanoparticles (Fe3O4@SiO2 MNPs)

All analytical grade reagents were obtained from MERCK (Saint Louis, MO, USA) and used as received without any further purification. Fe3O4@OA MNPs were obtained by co-precipitation method, following the procedure described in ref. [32] with some modifications. For this, iron(III) chloride hexahydrate (FeCl3·6H2O, 45 mmol) and iron(II) sulfate heptahydrate (FeSO4·7H2O, 30 mmol) were dissolved in 100 ml of 10 mmol hydrochloric acid (HCl) aqueous solution with mechanical stirring. The mixture was heated up to 60 °C, then ammonium hydroxide (NH3 aq, 770 mmol) and oleic acid (OA, 7.1 mmol) were added, and the reaction was carried out for 1 h. After that, the obtained MNPs were transferred to a beaker and placed on a hot plate at 100 °C to allow flocculation. The precipitate containing Fe3O4@OA MNPs was separated from the reaction medium by a magnetic field and washed three times with Milli-Q water (Millipore®, Burlington, MA, USA). Finally, Fe3O4@OA MNPs were re-dispersed in cyclohexane (CHX) and the remaining water was completely removed from the organic phase by using a decantation funnel. The total solid content was determined by thermogravimetric analysis (TGA, Perkin Elmer model 7, Waltham, MA, USA): Wmag = 4.2% by weight.

Starting from Fe3O4@OA MNPs, core-shell Fe3O4@SiO2 MNPs were prepared according to a water-in-cyclohexane reverse microemulsion process as reported in ref. [33] with some modifications. Briefly, 77 mg of Fe3O4 MNP@OA dispersed in CHX were added to a mixture of Igepal CO-520 (19.5 mmol) and CHX (2 mol). The mixture was stirred at 350 rpm at room temperature for 30 min. Then, NH3 aq (15 mmol) and tetraethyl orthosilicate (TEOS, 10.7 mmol) were added, the mixture was covered with aluminium foil, and stirred for 16 h at room temperature. The obtained Fe3O4@SiO2 MNPs were washed 4 times using 2-propanol (IPA). For each wash, the MNPs were retained with a magnet and the supernatant was removed. Finally, the MNPs were washed twice with Milli-Q water and centrifuged at 9000 rpm for 10 min. The silica coated magnetite nanoparticles were redispersed in Milli-Q water. The total solids content was determined by TGA: Wmag = 1.33% by weight. The synthesis process is visually described in Fig. 2.

Fig. 2
figure 2

Sketch of the methods for Fe3O4@SiO2 MNPs synthesis as detailed in the text

Structural characterization

The MNPs were characterized by different techniques to assess their physical and chemical properties. Morphology was characterized by transmission electron microscopy (TEM) using a JEOL JEM-1011 microscope (JEOL, Tokyo, Japan) operating at 100 KV. In addition, the structure and properties of the MNPs were analyzed at the atomic scale in a selected area by electron diffraction (SAED) with High Resolution TEM LIBRA 200FE (HRTEM, Carl Zeiss NTS GmbH, Oberkochen, Germany) operating at 200 KV. TEM micrograph of Fe3O4@SiO2 MNPs (Fig. 3a) shows a spherical morphology with a diameter around 20 nm, where magnetite cores (dark contrast) are embedded inside the silica shell (bright contrast). It can be appreciated that the reverse microemulsion method allowed the development of an excellent silica coating and a very narrow size distribution as shown in Fig. 3b. The HRTEM image (Fig. 3c) confirms the crystalline nature of the magnetite nanoparticles. A typical magnetization curve for NP is shown in Fig. 3d.

Fig. 3
figure 3

Morphological, structural, and magnetic characterization of Fe3O4@SiO2 MNPs: a TEM image, b particle size distribution, c HRTEM image of Fe3O4@OA MNPs (magnetic core) showing lattice fringes with d-spacing of 0.20 nm, which is a characteristic of the (400) magnetite structure, and d hysteresis loop at room temperature

The sample shows negligible coercive fields (HC=3.5 Oe) and remanence (MR=0.6 emu/g), corresponding to a superparamagnetic (SP) behaviour. The saturation magnetization of 63 emu/gFe3O4 is comparable with the highest values reported in literature for iron oxide SP-MNP [34]. Surface functional groups of dried MNPs were analyzed by Fourier Transform Infrared (FTIR) Spectroscopy with a Thermo Nicolet Nexus spectrometer (Thermo Fisher Scientific, Madrid, Spain) using the attenuated total reflectance (ATR) in the range of 4000 − 400 cm− 1 and are shown in Fig. 4. Silica coating can be confirmed by the appearance of three peaks at 1069, 452 and 792 cm− 1, corresponding to the stretching modes of Si-O-Si (asymmetric and symmetric) and the scissoring vibration of Si-O-Si, respectively [35]. The hydrodynamic radius of 30 nm was measured for these MNPs in aqueous solution via Dynamic Light Scattering by a Malvern Nano ZS (Malvern Instruments, Malvern, UK).

Fig. 4
figure 4

FTIR spectrum of the magnetite nanoparticles (blue pattern) and silica-coated magnetite nanoparticles (black pattern), with the characteristic bands as evidence

Surface modification with hyperbranced KVLFF

Synthesis of branched KLVFF aptamers

Molecular recognition of the selected biomarker is ensured by MNP surface functionalization with short peptides having binding affinity to specific regions of the Aβ1−42 and chemical stability [36]. Among them, the sequence KLVFF has been identified as one of the most effective one as it specifically binds to the homologous regions of Aβ1−42 [37].

Branched poly(epsilon-lysine) peptides - starting with an Arginine (R) molecule followed by the branching in 3 generations of poly(epsilon-lysine), and exposing the KLVFF aptamer sequence at each of the 16 uppermost molecular branches [RGen3K(KLVFF)16] - were assembled using a common 9-fluorenylmethoxycarbonyl (Fmoc) solid phase peptide synthesis (SPPS) by a microwave synthetiser (Biotage ® Initiator, Ystrad Mynach UK). A linear aptamer including a spacer of two Glycine molecules was also synthesised and later used as control in the MNP surface functionalisation to discriminate any negative effect (e.g. steric hindrance) that the larger branched aptamer has in the process of coupling to the nanoparticles.

Initially, 0.5 g of Tenta Gel S NH2 resin (Iris Biotech GmbH, Marktredwitz, Germany) was swollen with 5 ml dimethylformamide (DMF) (Fisher Scientific, Loughborough, UK), for 15 minutes. After intensive washes with 3 ml of DMF, the resin was coupled to the C-gorup of an amide linker, Fmoc Rink Amide Linker (Merck KGaA, Darmstadt, Germany), sonicated with 3 ml of DMF containing 0.4 mmol O-Benzotriazole-N,N,N’,N’-tetramethyl-uronium-hexafluoro-phosphate (HBTU) (Novabiochem, London, UK) and 0.8 mmol N,N-Diisopropylethylamine (DIPEA) (Merck KGaA, Darmstadt, Germany) used as activation agents. Reaction mixture was performed at 50 °C and 50 W for 6 min. The linker was then washed three times with DMF and its Fmoc-group was removed using 20% v/v piperidine (Merck KGaA, Darmstadt, Germany) in DMF following two deprotection steps at room temperature for 4 min/each. The aptamers were again washed three times in 5 ml of DMF while revealing new N-terminal amine that supported the assembly of an ordinate series of Fmoc-amino acids. After all amino acids were added by series of coupling and deprotection steps, all aptamers were allowed to stand for 30 min for final deprotection under stirring at 900 rpm and high absorption and transferred to a 10 mL fritted syringe through a series of washes with 40 ml dichloromethane, methanol and diethylether (Fisher Scientific, Loughborough, UK). Then, they were dried and weighed prior to be cleaved from the resin.

The final branched macromolecules were isolated from resin using a specific cleavage cocktail: 95% v/v trifluoroacetic acid, (TFA) (Fisher Scientific, Loughborough, UK) 2.5% v/v deionized water and 2.5% v/v trisopropylsilane (TIPS) (Merck KGaA, Darmstadt, Germany). After three hours incubation, each aptamer solution was passed down a Pasteur pipette filled with 1 cm of a glass wool and the crude aptamers were collected in a tube containing 20 ml of chilled diethylether (Fisher Scientific, Loughborough, UK) and centrifuged by a Denley BS400 centrifuge (Denley Instruments, Cambridge, UK) for three times at 3500 rpm for 5 min. Afterwards, aptamers were freeze dried using a Christ Alpha 2–4 LSC freeze-drier (SciQuip LTD, Wem, UK), dissolved in pure methanol and filtered through a syringe filter with a pore diameter of 0.25 μm (GE Healthcare, Amersham, UK) prior to their characterization.

Chemical coupling of Rgen3K(KLVFF)16 and linear GG-KLVFF on to Fe3O4@SiO2 MNPs surface

200 mg of MNPs of Fe3O4@SiO2 MNPs were taken from a 10 mg/ml concentration solution. The MNPs were centrifuged three times at 3500 rpm for 5 min, then the supernatant was removed and the MNP were left to air-dry for 48 h. 2 mg of Fe3O4@SiO2 MNPs were weighed and underwent a mild treatment with 3.0% (v/v) hydrogen peroxide to induce the formation of free hydroxyl radicals from the oxygen groups of silica. This consisted in a quick sonication in the hydrogen peroxide solution followed by 15 min incubation under orbital shaking. The Fe3O4@SiO2 MNPs were resuspended at a final concentration of 1 mg/ml in 2 ml of 0.1 mol MES buffer (pH 6.5) containing 0.2 mmol 1-Ethyl-3-(3-dimethylamino-propyl)carbodiimide (EDC) (Merck KGaA, Darmstadt, Germany) and 0.05 mmol N-Hydroxy-succinimide (NHS) (Merck KGaA, Darmstadt, Germany) to derivatise the hydroxyl groups into amino groups. The Fe3O4@SiO2 MNPs were rapidly sonicated and incubated with on an orbital shaker for 2 h at room temperature. The incubation medium was removed and the Fe3O4@SiO2 MNPs washed three times with deionised water by spinning them down at 3500 rpm for 5 min and finally conjugated with 50 ml solution of either aptamer solution (10 mg/ml) for 2 h at room temperature to promote the formation of peptide bonds of the aptamer with the derivatised Fe3O4@SiO2 MNPs surface. The MNPs were washed with deionised water three times and left to air-dry overnight. Prior to experiments of Aβ1− 42 capturing, control SiO2@MNP and RGen3K(KLVFF)16-functionalised MNPs were resuspended in Nanosperse® (Tissue Click Ltd, Brighton and Hove, UK), a biocompatible nanoparticle aqueous dispersant medium.

Material characterization

The pure solid-phase synthesis of branched KLVFF aptamers was demonstrated as a single peak in high-performance liquid chromatography (HPLC) spectra and FTIR indicated the successful functionalization of MNP with the branched aptamer (Fig. 5). As a control, MNP surface functionalization was also performed with single KLVFF sequence to which a Glycine-Glycine spacing arm was added instead of the branched poly(epsilon-Lysine). The emergence of peaks in the typical region of primary and secondary amines are clearly visible on MNPs functionalized with the hyperbranched aptamers. A hydrodynamic radius of 300 nm was measured for the KLVFF-functionalized MNPs via Dynamic Light Scattering by a Malvern Nano ZS (Malvern Instruments, Malvern, UK).

Fig. 5
figure 5

FTIR of the SiO2@MNP functionalised with a GG-KLVFF and RGen3K(KLVFF)16 branched aptamer

Results and discussion

Controlled transport of MNPs

In the device here described, the separation, concentration, and manipulation of Aβ1− 42 molecules is based on magnetically-controlled transport of MNPs through the two-turn spiral. It enables the concentration of MNPs into a dense CSC plug between the magnets from the nearby section of the silicone tube, the subsequent accumulation of more MNPs into the same plug as the magnets move along the spiral and, finally, the delivery of all the MNPs initially dispersed in the solution at the device’s outlet as shown in Fig. 6 (in the following the different phases of the process are indicated by the letter in the relative image of Fig. 6). The specific functionalization of the MNPs allows the capture of Aβ1− 42 molecules on their surface and ultimately their manipulation. At the beginning of the experiment, the KVLFF-functionalized MNPs were suspended in a Aβ1− 42 Lumipulse® calibration solution (Fujirebio, Gent, Belgium) of known concentration and diluted in buffer with chemical stabilizers and, as preservative, 0.1% 2-pyridinol-1-oxide to avoid amyloids degradation. Then, 100 µl of this suspension (roughly the two-turn spiral volume) was injected by suction through the inlet using an infusion pump (Harvard-Apparatus PhD-ultra, Holliston, MA, USA) with a flow rate of 500 µl/min. The injection was done with the magnets at the inlet. After the capillary was filled, we waited roughly 10 min to concentrate MNPs into a CSC between magnets (a). Then, the magnets started running from the initial position at the inlet (b) and rotated for 3.5 h covering the two-loop tubing at a speed of 40 μm/sec. This value assures that the CSC remains stable while moving along the capillary as the chosen speed sits in the middle of the “stability window” defined in [30]. Because the silicone tube is transparent, it is possible to visually follow the progression of the MNP droplet following the magnets. The MNPs are progressively concentrated between the magnets as they travel along the two-turn spiral. At the beginning, MNPs are concentrated in both the spiral turn (c). As the magnets travel to the output (d), the MNPs in the external turn reach the junction with the output and there they remain while the ones in the internal turn keep on following the magnets for a second round (passing from the internal to the external turn) (e). Finally, when the magnets reach for the second time the junction all MNPs were collected in a dense plug located at the output (f). In this way, we ensure that the complete sample was systematically scanned by the KVLFF-functionalized MNPs for the targeted Aβ1− 42 molecules. As detailed in [30], the dynamics of the MNPs magnetically trapped in this device is dictated by the magnetic force. Indeed, once a MNP is attracted in the region between the magnets, the magnetic energy dominates over the thermal energy responsible for the destabilizing effects of the Brownian motion. This assures an efficient manipulation of MNPs independently of their hydrodynamic radius, such as bare MNPs, KLVFF-functionalized MNPs and finally KLVFF-functionalized MNPs bond with Aβ1− 42 molecules.

Fig. 6
figure 6

Controlled transport of MNPs. Time is given in hr:min format

Assessing Aβ1−42- KVLFF functionalized MNPs binding probability

The capture, separation, and transport of Aβ1−42 by KVLFF-functionalized MNPs has been experimentally demonstrated comparing the Aβ1−42 concentration in the fluid before and after being processed by the above-described device. It is a differential measurement: knowing the initial concentration of Aβ1−42 in the injected fluid and measuring it at the end of the experiment, the binding probability can be calculated as the difference. The initial concentration was measured in the standard solution before mixing it with MNPs at the beginning of the experiment. The supernatant fluid (in the tubing part before the cut) is then recovered to measure the concentration of the non-trapped Aβ1−42 at the end of the experiment. To this aim, the tube is cut by non-magnetic scissors just before the position of the magnets when they arrive to the final point and the supernatant fluid therein contained is analyzed.

To measure Aβ1− 42 concentrations we used a LUMIPULSE® G600II instrument (Fujirebio, Ghent, Belgium). It is a magnetic-bead-based immunoassay automated system accepted for clinical analysis of human CSF samples. To detect Aβ1− 42, it automatically adds, after a washing step, streptavidin-conjugated alkaline phosphatase (AP) to the biotinylated monoclonal antibody on the beads. Subsequently, those beads bind onto 3-(2′-spiroadamantane)-4-methoxy-4-(3ʺ-phosphoryloxy) phenyl-1, 2-dioxetane disodium salt (AMPPD) used as substrate. The luminescence at 477 nm is finally measured to give a quantitative estimate of the amyloid concentration.

An Aβ1-42 – MNP binding probability as high as 90% was obtained. This value was achieved at Aβ1-42 concentration of 1 ng/ml and MNP concentration of 5 µg/ml to have a 1:1 ratio between nanoparticles and amyloids (Table 1). Indeed, as the mass of one nanoparticle is 37‧10–18 g and the mass of one Αβ1-42 molecule is 7.47‧10-21 g) the ratio in terms of mass must be 5000:1 to have an equal number of MNPs and Αβ1-42 in the solution. For the sake of completeness, in Table 1 are shown also the raw experimental results of the measured concentration in each experiment. This is the value measured by Lumipulse® after applying the dilution factor as we need to match the fluid volume processable by Lumipulse® (~ 150 µl). The experimental procedure is sketched in Fig. 7.

Table 1 Experimental data on binding rate between KVLFF-functionalized MNPs and Aβ1− 42 molecules when they are mixed in 1:1 numerical ratio in the experimental device. Data refer to amyloid concentration, as measured by Lumipulse®, in the supernatant solution after the magnets completed two rotations to cover the two-loop spiral as detailed in the text. The binding ratio is calculated as the difference between the initial concentration and the one after the process
Fig. 7
figure 7

Sketch of the experimental procedure used to assess Aβ1-42-MNPs binding probability. Dilution is needed to match the fluid volume processable by Lumipulse® with the one contained in the experimental device. Numerical values of concentrations are given in the figure for the numerical ratio 1:1

Control experiments have been performed with bare (non-aptamer-functionalized) MNPs, and no decrease in the Aβ1-42 concentration have been measured (Table 2) within the statistical variability in the Lumipulse® measurements valued in 50 pg/ml. It demonstrates the specific molecular binding between Aβ1-42 and RGen3K(KLVFF)16 branched aptamers chemically bonded onto the MNPs surface

Table 2 Experimental data on binding rate between non-functionalized MNPs and Aβ1−42 molecules when they are mixed in 1:1 numerical ratio. The experimental procedure behind is the same as for the data in Table 1. No decrease in the Aβ1−42 concentrations has been measured

Due to the tendency of Aβ1−42 to adhere onto plastic surfaces [12], unspecific adhesion of Aβ1−42 on the medical-grade silicone tube has been included in the analysis by injecting a Aβ1−42 solution into a silicone tube and let the solution static for 3.5 h (magnets running time). No measurable change of Aβ1−42 concentration has been measured (Table 3)

Table 3 Experimental data on unspecific adhesion of Aβ1−42 molecules on medical grade silicone. No decrease in the Aβ1−42 concentration has been measured. Note that the Aβ1−42 concentration used in this experiment is roughly 2/3 of the ones used in the experiments of Tables 1 and 2

In summary, the experimental procedure here described allows: (1) to maximize the binding probability of the MNPs with the Aβ1−42 molecules; and (2) to retrieve most (if not all) the Aβ1−42 molecules sparsely distributed within a large volume of fluid. Because of the low concentration, the binding probability would have been negligible if the Aβ1−42 molecules and the MNPs were left free to move in the solution by Brownian motion. Instead, in the device the MNPs are attracted by the magnets to form a plug with the CSC configuration optimized for Aβ1−42 capture. Also, the magnetic field generated by the magnets would not be able to cover the entire spiral - or, more generally, any macroscopic volume – but, moving the magnets along the spiral, allows them to collect the particles at any point when the magnets will pass by. Even though, some Aβ1−42 can be captured by randomly meeting free MNPs in the solution, the dominant process of molecular binding is by mean of the MNPs densely packed in the magnetically-actuated CSC plug. The working principle of the device thus allows, after the complete rotation, the concentration of virtually all (~ 90%) the Aβ1−42 molecules dispersed in a macroscopic volume of 100 µl into a dense plug of ca. 50 nl that, theoretically, can be analyzed by ultra-sensitive nanosensors. Also, larger volumes can be processed as more loops in the spiral design can be added to accommodate larger amount of analyte.

A series of experiments has been performed by systematically varying the numerical ratio between MNPs and molecules. Four different ratios (Αβ 1-42: MNP), were tested: 3:1; 1:1; 1:3 and 1:10. As shown in Fig. 8, with 1:1 or lower ratios, we obtained similar binding rates of around 80% whose difference lies within the experimental error. Indeed, using a one-way analysis of variance (ANOVA) followed by Tukey’s multiple comparison test (P < 0.05), no statistical difference was observed. Instead, a significantly lower value of ~ 30% was obtained with the 3:1 ratio. These results indicate that increasing the number of MNPs beyond the parity with the Αβ1-42 molecules does not significantly increase the binding efficiency whereas, when the Αβ1-42 molecules outnumber the MNPs, we observe a drastic decrease. Interestingly, the binding rate in the 3:1 experiment (where there are three molecules for each MNP) is consistent with the hypothesis where one MNP binds with just one molecule, as, in such case, just a third of the molecules can be captured. On the other hand, lowering the Αβ 1-42: MNP ratio to 1:10 – thus in a condition where the MNPs outnumber the Αβ 1-42 molecules by a factor of 10 – the binding rate remains constant. Taken together, these experimental results offer the tantalizing view of a one-to-one molecular binding where each nanoparticle binds with just one Aβ1-42 molecule. Because of the need to provide a volume of fluid suitable for the Lumipulse® analysis, we chose to use a dilution factor of 1/3 in this experimental series to have a homogeneous set of data. The decrease in the binding rate for the 1:1 ratio experiments with different dilution factors from 90% to 1/5 (Table 1) to 78% for 1/3 (Table 4) is apparent but it can be explained by the lower concentration of the Aβ1-42 molecules in the experiment with 1/3 dilution factor. Interestingly, the cubic root of the ratio between the concentrations used (600 pg/ml and 1000 pg/ml) – a quantity related with the ratio of the molecular free path – is very similar to the ratio of the binding rate with the respective concentrations. This hints that the decrease in the binding rate is due to the fact the molecules are more dispersed when using lower concentration and thus the probability for them to meet the MNP is also smaller. The technology here presented can thus achieve a control on molecular scale on capture, separation, and transport of proteins in macroscopic samples over macroscopic distances.

Fig. 8
figure 8

Quantitative analysis of the molecular binding between Αβ1 − 42 and KLVFF-functionalized MNPs as a function of the numerical ratio Αβ1 − 42: MNP (green histograms). As a control it is shown the binding ratio between bare MNPs (grey histograms). Aβ1 − 42 concentrations for the experiments with 1:1 and 1:3 ratios – 600 pg/ml and 200 pg/ml, respectively – are usually found in clinical samples. 600 pg/ml (1:1 ratio in the figure) in particular is considered the cut-off value for early AD diagnosis [39, 40]

Table 4 Experimental data on binding rate between KVLFF-functionalized MNPs and Aβ1−42 molecules when they are mixed with different numerical ratios in the experimental device. The experimental procedure behind is the same as for the data in Table 1

Conclusion

Even though the treatment for late-stage AD remains a distant prospect, a first example of a drug able to slow cognitive decline in patients with early AD has been recently published [8]. This highlights the critical importance of an AD early diagnosis. Moreover, it is broadly accepted that many potential therapies are being used too late and only after consistent neuronal damage was established. Aβ species from CSF are widely recognized as an optimal biomarker for an early detection of the disease; yet, the utility of Aβ1−42 as a robust biomarker in clinics is still questioned due to technical challenges in its measurement [12, 38]. The development of automatized low-cost point-of-care (PoC) diagnostic tools can solve many clinical and analytical impediments and the device here presented has several innovative technological characteristics for this application; namely, (1) it does not require microfluidic pumps/switches or elaborated chip design; (2) the capture/binding process occurs in a reservoir of static fluid by magnetic nanoparticles that travels through the fluid actuated by external magnetic fields. This reduces the need of pumps or metering to control the flux of fluid in the apparatus as the pump is used only to fill the capillary at the beginning of the experiments; (3) the separation of Aβ1−42 molecules from the solution is done, with very high efficiency, without using any membrane; (4) the processes of separation, concentration and molecular transport is done simultaneously.

In this study a new technology has been developed to capture, separate, and manipulate a molecular biomarker, Aβ1−42, in a concentration range relevant for AD diagnosis in clinical practice: 500–1000 pg/ml [39, 40]. It is based on functionalized MNPs actuated by external magnetic fields and an efficiency of 90% in biomarker extraction has been experimentally demonstrated with clinically-relevant volumes of solution. Moreover, such efficiency can be easily improved via dedicated engineering. Owing the scalability of the magnetic fields, the technology can be smoothly adapted to various clinical settings and needs. Noteworthy, it is also compatible with the materials currently used in hospitals and medical laboratories. Still, in spite of the convincing demonstration performed in laboratory conditions, we are aware that further studies using real CSF samples form patients at different level of cognitive impairment are required for a clinical validation of this technology.

Finally, although demonstrated for Aβ1−42, the technology here presented is not restricted to this but can be applied to a variety of molecular biomarkers: for example, among the others, to monitor bone metastases in oncology [41] or to assess radiation injury [42]. It can also lay the foundations for versatile and ultrasensitive platforms for viral detection [43, 44].

Data availability

All data associated with this study are available in the main text.

References

  1. Scheltens P, De Strooper B, Kivipelto M, Holstege H, Chétalat G, Teunissen CE, Cummings J, van der Flier WM. Alzheimer’s disease. Lancet. 2021;397:1577–90.

    Article  CAS  PubMed Central  Google Scholar 

  2. Jack CR Jr, Knopman DS, Jagust WJ, Petersen RC, Weiner MW, Aisen PS, Shaw LM, Vemuri P, Wiste HJ, Weigand SD, Lesnick TG, Pankratz VS, Donohue MC, Trojanowski JQ. Tracking pathophysiological processes in Alzheimer’s disease: an updated hypothetical model of dynamic biomarkers. Lancet Neurol. 2013;12:207–16.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  3. Musiek ES, Holtzman DM. Three dimensions of the amyloid hypothesis: time, space and wingmen. Nat Neurosci. 2015;18:800–6.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  4. Fagan AM, Mintun MA, Mach RH, Sang-Yoon L, Dence CS, Shah AR, LaRossa GN, Spinner ML, Klunk WE, Mathis CA, DeKosky ST, Morris JC, Holtzman DM. Inverse relation between in vivo amyloid imaging load and cerebrospinal fluid Aβ42 in humans. Ann Neurol. 2006;59:512–19.

    Article  CAS  PubMed  Google Scholar 

  5. Le Bastard N, Martin JJ, Vammechelen E, Vanderstichele H, De Deyn PP. Engelborghs S.Added diagnostic value of CSF biomarkers in differential dementia diagnosis. Neurobiol Aging. 2010;31:1867–76.

    Article  PubMed  Google Scholar 

  6. Dubois B, Feldman HH, Jacova C, Hampel H, Molinuevo JL, Blennow K, Dekosky ST, Gauthier S, Selkoe D, Bateman R, Cappa S, Crutch S, Engelborghs S, Frisoni GB, Fox NC, Galasko D, Habert M-O, Jicha GA, Nordberg A, Pasquier F, Rabinovici G, Robert P, Rowe C, Salloway S, Sarazin M, Epelbaum S, de Souza LC, Vellas B, Visser PJ, Schneider L, Stern Y, Scheltens P, Cummings JL. Advancing research diagnostic criteria for Alzheimer’s disease: the IWG-2 criteria. Lancet Neurol. 2014: 13, 614–29.

  7. Cohen AD, Landau SM, Snitz BE, Klunk WE, Blennow K, Zetterberg H. Fluid and PET biomarkers for amyloid pathology in Alzheimer’s disease. Mol Cell Neuroscience. 2019;97:3–17.

    Article  CAS  Google Scholar 

  8. van Dyck CH, Swanson CJ, Aisen P, Bateman RJ, Chen C, Gee M, Kanekiyo M, Li D, Reyderman L, Cohen S, Froelich L, Katayama S, Sabbagh M, Vellas B, Watson D, Dhadda S, Irizarry M, Kramer LD, Iwatsubo T. Lecanemab in early Alzheimer’s disease. New Eng J Med. 2023;388:9–21.

    Article  PubMed  Google Scholar 

  9. Blennow K, Zetterberg H. Biomarkers for Alzheimer’s disease: current status and prospect for the future. J.Int.Med. 2018: 284, 643–63.

  10. Blennow K, Mattsson N, Schöll M, Hansson O, Zetterberg H. Amyloid biomarkers in Alzheimer’s disease. Trends Pharmacol Sci. 2015;36:297–309.

    Article  CAS  PubMed  Google Scholar 

  11. Mattsson N, Andreasson U, Persson S, Carrillo MC, Collins S, Chalbot S, Cutler N, Dufur-Rainfray D, Fagan AM, Heegaard NHH, Hsiung G-YR, Hyman B, Iqbal K, Lachno DR, Lleó A, Lewczuk P, Molinuevo JL, Parchi P, Regeniter A, Rissman R, Rosenmann H, Sancesario G, Schröder J, Shaw LM, Teunissen CE, Trojanowski JQ, Vanderstichele H, Vandijck M, Verbeek MM, Zetterberg H, Blennow K. Käser SA and the Alzheimer’s Association QC Program Work Group. CSF Biomarker variability in the Alzheimer’s Association quality control program. Alzheimer’s&Dementia 2013: 9, 251–61.

  12. Perret-Liaudet A, Pelpel M, Tholance Y, Dumont B, Vanderstichele H, Zorzi W, ElMoualij B, Schraen S, Moreaud O, Gabelle A, Thouvenot E, Thomas-Anterion C, Touchon J, Krolak-Salmon P, Kovacs GG, Coudreuse A, Quadrio I, Lehmann S. Risk of Alzheimer’s disease biological misdiagnosis linked to cerebrospinal collection tubes. J Alzheimers Dis. 2012;31:13–20.

    Article  PubMed  Google Scholar 

  13. Van Thanh Nguyen N, Taverna M, Smadja C, Mai TD. Recent electrokinetic and microfluidic strategies for detection of amyloid beta peptide biomarkers: towards molecular diagnosis of Alzheimer’s disease. Chem.Rec. 2021: 21, 149–61.

  14. Wu K, Su D, Liu J, Saha R, Wang J-P. Magnetic nanoparticles in nanomedicine: a review of recent advances. Nanotechnology. 2019;30:502003.

    Article  CAS  PubMed  Google Scholar 

  15. Squires TM, Quake SR. Microfluidics: fluid physics at the nanoliter scale. Rev Mod Physics. 2005;77:977–1026.

    Article  CAS  Google Scholar 

  16. Kiplagat A, Martin DR, Onani MO, Meyer M. Aptamer-conjugated magnetic nanoparticles for the efficient capture of cancer biomarker proteins. J.Magn.Magn.Mat. 2020: 497, 166063.

  17. Tang C, He Z, Liu H, Xu Y, Huang H, Yang G, Xiao Z, Li S, Liu H, Deng Y, Chen Z, Chen H, He N. Application of magnetic nanoparticles in nucleic acid detection. J Nanobiotechnol. 2020;18:62.

    Article  Google Scholar 

  18. Zhao Z, Cui H, Song W, Ru X, Zhou W, Yu X. A simple magnetic nanoparticles-based viral RNA extraction method for efficient detection of SARS-Co-V-2. bioRxiv 2020.02.22.961268 (2020).

  19. Cudjoe KS, Krona R. Detection of Salmonella from raw food samples using Dynabeads® anti-Salmonella and a conventional reference method. Int J Food Microbiol. 1997;37:55–62.

    Article  CAS  PubMed  Google Scholar 

  20. Vardal F, Gaudernack G, Funderud S, Bratile A, Lea T, Ugelstad J, Thorsby E. HLA class I and II typing using cells positively selected from blood by immunomagnetic isolation–a fast and reliable technique. Tissues Antigens. 1986: 28, 301–12.

  21. Saei A, Asfia S, Kouchakzadeh H, Rahmandoust M. Antibody-modified magnetic nanoparticles as specific high-efficient cell-separation agents. J Biomed Mater Res. 2020;108B:2633–42.

    Article  CAS  Google Scholar 

  22. Yang J, Pan B, Zeng F, He B, Gao Y, Liu X, Song Y. Magnetic colloid antibodies accelerate small extracellular vesicles isolation for point-of-care diagnostics. NanoLett. 2021: 21, 2001–9.

  23. Ramadan Q, Gijs MAM. Simultaneous sample washing and concentration using a trapping-and-releasing mechanism of magnetic beads on a microfluidic chip. Analyst. 2011;136:1157–66.

    Article  CAS  PubMed  Google Scholar 

  24. Johansson LE, Gunnarsson K, Bijelovic S, Eriksson K, Surpi A, Göthelid E, Svedlindh P, Oscarsson S. A magnetic microchip for controlled transport of attomole levels of proteins. Lab.Chip. 2010: 10, 654–61.

  25. Lee CS, Lee H, Westervelt RM. Microelectromagnets for the control of magnetic nanoparticles. Appl Phys Lett. 2001;79:3308–10.

    Article  CAS  Google Scholar 

  26. Donolato M, Vavassori P, Gobbi M, Deryabina M, Hansen MF, Metlushko V, Ilic B, Cantoni M, Petti D, Brivio S, Bertacco R. On-chip manipulation of protein-coated magnetic beads via domain-wall conduits. Adv Mat. 2010;22:2706–10.

    Article  CAS  Google Scholar 

  27. Wang J, Morabito K, Erkers T, Tripathi A. Capture and separation of biomolecules using magnetic beads in a simple microfluidic channel without an external flow device. Analyst. 2013;138:6573–81.

    Article  CAS  PubMed  Google Scholar 

  28. Tarn MD, Peyman SA, Pamme N. Simultaneous trapping of magnetic and diamagnetic particle plugs for separations and bioassays. RCS Adv. 2013;3:7209–14.

    CAS  Google Scholar 

  29. Blümler P. Magnetic guiding with permanent magnets: concept, realization and applications to nanoparticles and cells. Cells. 2021;10:2708.

    Article  PubMed  PubMed Central  Google Scholar 

  30. Surpi A, Shelyakova T, Murgia M, Rivas J, Piñeiro Y, Greco P, Fini M, Dediu VA. Versatile magnetic configuration and manipulations for the control and manipulation of superparamagnetic nanoparticles. Sci Rep. 2023;13:5301.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  31. Willemse EAJ, Tijms BM, van Berckel BNM, Le Bastard N, van der Flier WM, Scheltens P, Teunissen CE. Comparing CSF amyloid-beta biomarker ratios for two automated immunoassays, Elecsys and Lumipulse, with amyloid PET status. Alzheimer’s Dement. 2021: 13, e12182.

  32. Gonzales Gomez MA, Belderbos S, Yañez-Villar S, Piñero Y, Cleeren F, Bormans G, Deroose CM, Gsell W, Himmelreich U, Rivas J. Development of superparamagnetic nanoparticles coated with polyacrylic acid and aluminum hydroxide as an efficient contrast agent for multimodal imaging. Nanomaterials. 2019;9:1626.

    Article  Google Scholar 

  33. Moldes-Diz Y, Gamallo M, Eibes G, Vargas-Osorio Z, Vazquez-Vazquez C, Feijoo G, Lema JM, Moreira MT. Development of a superparamagnetic laccase nanobiocatalyst for the enzymatic biotransformation of xenobiotics. J Environ Eng. 2018;144:04018007.

    Article  Google Scholar 

  34. Karaagac O, Kockar H. A simple way to obtain high saturation magnetization for superparamagnetic iron oxide nanoparticles synthesized in air atmosphere: optimization by experimental design. J.Magn.Magn.Mat. 2016: 409, 116–23.

  35. García Acevedo P, González Gómez MA, Arnosa Prieto A, De Castro Alves L, Seco Gudiña R, Piñeiro Y, Rivas J. Fluorescent single-core and multi-core nanoprobes as cell trackers and magnetic nano heaters. Magnetochemistry. 2022;8:83.

    Article  Google Scholar 

  36. Baig MH, Ahmad K, Rabbani G, Choi I. Use of peptides for the management of Alzheimer’s disease: diagnosis and inhibition. Front.Aging.Neurosci. 2018: 10, 21.

  37. Watanabe K-I, Nakamura K, Akikusa S, Okada T, Kodaka M, Konakahara T, Okuno H. Inhibitors of fibril formation and cytoxicity of β-amyloid peptide composed of KLVFF recognition element and flexible hydrophilic disrupting element. Biochem Biophys Res Commun. 2002;290:121–4.

    Article  CAS  PubMed  Google Scholar 

  38. Rozga M, Bittner T, Höglund K, Blennow K. Accuracy of cerebrospinal fluid Aβ1–42 measurements: evaluation of pre-analytical factors using a novel Elecsys immunoassay. Clin Chem Lab Med. 2017;55:1545–54.

    Article  CAS  PubMed  Google Scholar 

  39. Gobom J, Parnetti L, Rosa-Neto P, Vyhnalek M, Gauthier S, Cataldi S, Lerch O, Laczo J, Cechova K, Clarin M, Benet AL, Pascoal TA, Rahmouni N, Vandijck M, Huyck E, Le Bastard N, Stevenson J, Chamoun M, Alcolea D, Lleó A, Andreasson U, Verbeek MM, Bellomo G, Rinaldi R, Ashton NJ, Zetterberg H, Sheardova K, Hort J, Blennow K. Validation of the LUMIPULSE automated immunoassay for the measurement of core AD biomarkers in cerebrospinal fluid. Clin Chem Lab Med. 2022;60:207–19.

    Article  CAS  PubMed  Google Scholar 

  40. Leitão MJ, Silva-Spínola A, Santana I, Olmedo V, Nadal A, Le Bastard N, Baldeiras I. Clinical validation of the Lumipulse G cerebrospinal fluid assays for routine diagnosis of Alzheimer’s disease. Alzheimer’s Res Ther. 2019;11:91.

    Article  Google Scholar 

  41. D’Oronzo S, Brown J, Coleman R. The role of biomarkers in the management of bone-homing malignancies. J Bone Oncol. 2017;9:1–9.

    Article  PubMed  PubMed Central  Google Scholar 

  42. Singh VK, Newman VL, Romaine PLP, Hauer-Jensen M, Pollard HB. Use of biomarkers for assessing radiation injury and efficacy of countermeasures. Expert Rev Mol Diagn. 2016;16:65–81.

    Article  CAS  PubMed  Google Scholar 

  43. Wang J, Lu P, Yan J, Zhang Y, Huang L, Ali Z, Liu B, Li Z, He N. Rapid and sensitive detection of RNA viruses based on reverse transcription loop-mediated isothermal amplification, magnetic nanoparticles, and chemiluminescence. J Biomed Nanotechnol. 2016;12:710–6.

    Article  CAS  PubMed  Google Scholar 

  44. Cui H, Song W, Ru X, Fu W, Ji L, Zhou W, Zhao Z, Qu G, Yu X-F, Jiang G. A simplified viral RNA extraction method based on magnetic nanoparticles for fast and high-throughput detection of SARS-CoV-2. Talanta. 2023;258:124479.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

Download references

Acknowledgements

The authors thank Tatiana Shelyakova for the key suggestions on the magnetic configuration and Federico Bona for technical assistance. Vitaly Goranov, Giulia Foschi, Mara D’Onofrio and Cristiano Paggetti deserve a distinct acknowledgement for helpful discussions.

Funding

This research has been funded from the European Union’s Horizon 2020 research and innovation programme under the projects MADIA - MAgnetic DIagnostic Assay for neurodegenerative disease – grant agreement n0 732678, BOW - Biogenic Organotropic Wetsuits – grant agreement n0 952183 and PANA - Promoting Active Agening: functional nanostructures for Alzheimer’s disease at ultra-early stages - grant agreement n0 686009. And from the Italian National Recovery and Reliance Plan (NRRP), part of the European Union’s NextGenerationEU programme, under the project ECOSISTER - ECOSystem for sustainable transition of Emilia-Romagna - ECS 00000033.

Author information

Authors and Affiliations

Authors

Contributions

AS designed the experimental device, performed the experiments and analysed the experimental results. MM designed and fabricated the experimental device. YP, MAGG and JR fabricated and characterized the MNPs. VP and MS functionalized the MNPs for Aβ1-42 immuno-capturing. PG performed the experiments. SL and FC performed the experiments and analysed the experimental results. VAD was in charge of project administration and funding acquisition. AS, FC and VAD conceptualized the experiments and wrote the manuscript. VAD and FC contributed equally to the work. All authors read and approved the final manuscript.

Corresponding authors

Correspondence to Alessandro Surpi, Francisco Campos or Valentin Alek Dediu.

Ethics declarations

Competing interests

The authors declare no competing interests.

Ethics approval and consent to participate

Not applicable.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Surpi, A., Murgia, M., López-Amoedo, S. et al. Magnetic separation and concentration of Aβ 1–42 molecules dispersed at the threshold concentration for Alzheimer’s disease diagnosis in clinically-relevant volumes of sample. J Nanobiotechnol 21, 329 (2023). https://doi.org/10.1186/s12951-023-02095-8

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s12951-023-02095-8

Keywords